Main page
»
LED Drivers
»
LED-Driver 12 VDC
»
LED power supply 12 VDC, 60 Watt, 5 A, open frame IP20
LED power supply 12 VDC, 60 Watt, 5 A, open frame IP20
LED power supply NTCV-12-060, open frame, Version METOLIGHT®
Constant Voltage Power Supply 12 VDC, 60 Watt, 5 A
High-performance quality LED driver Pf> 0.95, open design for installation in control cabinets, short circuit proof, overvoltage protected. The open design gives the best cooling.
The power supply is ideal for operating LED lights, LED strips, wallwashers and other lights that are powered by 12 VDC.
It complies with standards EN60950-1, EN55022, EN61000-4-2, -4, -5, -11
Integrated protection circuits against over voltage, over current, over temperature with auto-recover function. This means, the driver recovers automatically after fault condition is removed. In the METOLIGHT® brand version specially manufactured for Asmetec, only high-quality and durable components are used.
Due to the open frame design, this power supply may only be installed in control cabinets.
Hints:
Installation only by the electrical engineer. If the polarity is incorrect, the LED strips may be irreparably damaged; in the event of a short circuit, the power supply unit may be damaged. Please make sure that the power of the power supply and the optional control unit is sufficient to supply the connected LED strips. Damage caused by incorrect installation or corrosion is not covered by the warranty.
We generally recommend power supplies to only 80% of their maximum power load.
Technical specifications:
- Input voltage: 180-255 VAC, 50/60 Hz
- Output voltage: 12 VDC, 5A
- Power: 60 watts max.
- Protection class: IP20
- Dimensions: 159 x 97 x 37 mm
- Weight: 0.5 kg
Technical Data
Beschreibung | Daten / Data | Description |
Markenname | METOLIGHT | Brand name |
Modell | POS-60-12-IP20 | Model |
EAN | EAN 4251192825087 | EAN |
Besonderheiten | Konstantspannung, aktive Schutzschaltung - constant voltage, active protection circuits | Specials |
Eingangsspannung | 180~255 VAC | Input Voltage |
Frequenz | 47 ~ 63 Hz | Frequency |
Gesamtleistung | 60 Watt | Input Power |
AC-Strom | 1A / 230VAC | AC current |
Anlaufzeit | < 0,5 sec | Setup time |
Leistungsfaktor | Pf > 0,80 | Power factor |
Leerlauf-Leistungsaufnahme | < 0,3 W | No Load Power Consumption |
Isolationsklasse | II | Isolation classs |
IP Schutzart | IP20 | IP Class |
Dimmbar? | nein / no | Dimmable? |
Ausgangsspannung | 12 VDC +/- 6% | Output Voltage |
regelbar | 10.8 ~ 13.2 V | adjustable |
Ausgangsstrom | 5,0 A +/- 2% | Output Current |
Störspannung | 120 mV p-p - 20 MHz | Ripplk&Noise |
Integrierter Schutz | Integrated Protections | |
Überspannung | max 20 V | Over Voltage |
Überstrom | 110~180% - auto recover | Over current |
Kurzschluß | hiccup mode - auto recover | Short Circuit |
Übertemperatur | - | Over Temperature |
Spannungsfestigkeit | In/Out: 1.5 kVAC - In/Gnd: 1.5 kVAC - Out/Gnd: 500VAC | Withstand Voltage |
Lagerung | -40°C ~ +80°C, 10~95% rH | Storage |
Arbeitstemperatur | -5°C ~ +45°C | Working Temperature |
Feuchtigkeit | 20 ~ 90% rH | Humidity |
Abmessungen | 159 x 97 x 37 mm (L x W x H) | Sizes |
Gehäuse | Metall | Housing |
Gewicht | 0,46 kg | Weight |
Weitere Infos | Bitte lesen Sie das technische Datenblatt - Please read the technical data sheet | More information |
Entspricht | CE, RoHS, 98/11/EC, UL | Complies |
Normen | EN 55032, EN 55024, EN 60950-1, EN 61000-4-2, -4, -5, -11, | Standards |
Hinweise | Notes |
Verwendungszweck | Application |
LED-Netzteil mit Konstantspannung 12 V DC zur Versorgung von LED-Leuchtmitteln mit entsprechenden Anschlusswerten | LED-driver constant voltage 12 V DC to feed suitable LED lights |
Besonderheiten | Specials |
LED-Netzteil mit integrierter Schutzschaltung, auto-recover | LED-driver with built in protection - auto-recover |
Installation | Installation |
Installation nur durch Elekrofachkraft unter Beachtung der allg. Vorschriften beim Umgang mit elektrischen Geräten und an Netzspannung. Installation darf nur an spannungsfrei geschalteten Anlagen und Leitungen erfolgen. | Installation only by expert watching the common rules when working with electricity and mains power. Installation only when power line is off. |
Hinweise | Notes |
Wie bei allen elektronischen Geräten ist auf ausreichende Luftzirkulation zu achten, damit die Netzteile nicht überhitzen. Wir empfehlen als maximale Anschlussleistung 80% der Nennleistung des Netzteils. Das Netzteil entspricht den aktuellen CE-Bestimmungen nach EN60950-1, EN55032, EN55024; EN61000-4-2, -4, -5, -11 | Make sure that there is sufficient air ventilation to avoid over heating. We recommend to charge the driver at max. 80% of nominal power. The driver complies with latest CE-regulations acc to EN60950-1, EN55032, EN55024; EN61000-4-2, -4, -5, -11 |
Entsorgung | Waste Treatment |
LED-Netzteile enthalten Wertstoffe. Bitte geben Sie die Netzteile nach Gebrauch beim Wertstoffhof ab oder senden Sie sie an Asmetec zum Recycling zurück. | LED-drivers contain valuable raw materials. Please dispose them after use at the Local Court of Value Materials or return them for free disposal to Asmetec. |
Hinweis zu den technischen Daten | Notes for technical data |
Die obigen Angaben entsprechen unserem aktuellen Wissensstand. Technische Daten die der Produktverbesserung dienen, können vom Hersteller ohne Vorankündigung geändert werden. Irrtum und Schreibfehler vorbehalten. | The above information corresponds to our current state of knowledge. Technical data used to improve the product may be changed by the manufacturer without prior notice. Errors and spelling mistakes excepted. |
Hinweise zu den Messwerten | Notes for measured data |
1. Alle Parameter werden mit Eingang 230VAC, Nennlast und 25 ° C Umgebungstemperatur gemessen. 2. Störspannungen werden bei Bandbreite 20MHz gemessen, mit 12" Twisted-Pair-Kabel mit einem 0,1 uF und parallelen Kondensator 47μF abgeschlossen. 3. Die Toleranzen beinhalten Anlauf, Netzregelung und Lastregelung. 4. Die Stromversorgung wird als als eine Komponente angesehen, die mit der endgültigen Ausrüstung in Kombination betrieben wird. Da EMV-Leistung durch die komplette Installation beeinflusst wird, muss die endgültige Ausstattung erneut qualifizieren werden. | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF i 47μF parallel capacitor. 3. Tolerance incudes set up tolerance, line regulation and load regulation. 4. Setup and rise time is measured from 0 to 90% rated output voltage. 5. Power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment must be re-qualify to comply with EMC Directives. |
Prüfberichte | Test Reports |
Individuelle Prüfberichte zu elektrischen und elektromagnetischen Daten erstellen wir auf Wunsch im eigenen Labor. | Individual test reports for electrical and electromagnetical data upon request made in own lab. |
Genereller Hinweis | General Note |
Die vorstehenden Angaben basieren auf dem aktuellen Stand unserer Kenntnisse. Unsere Angaben enthalten keine Zusicherung von Eigenschaften. Die Verwendung unserer Produkte durch unsere Kunden unterliegt den verschiedensten Bedingungen, sodass kein Kunde von der Eigenerprobung der Verwendbarkeit unserer Produkte entbunden ist. Eine Haftung für Folgeschäden ist in jedem Fall ausgeschlossen. Für Schäden, die sich aus der Verwertung unserer Angaben ergeben, haften wir nur, wenn uns Vorsatz oder grobe Fahrlässigkeit nachgewiesen werden kann. | The above information is based on the current state of our knowledge. Our information does not contain any assurance of properties. The use of our products by our customers is subject to a variety of conditions, so that no customer is released from testing the usability of our products. Liability for consequential damages is excluded in any case. We shall only be liable for damages resulting from the use of our information if intent or gross negligence on our part can be proven. |