Main page
»
LED Illumination
»
LED Tubes
»
LED-Tube T5
»
LED-Tube T5T6-145-25-DWM, T5, 1448 mm, 25 Watt, pure white
LED-Tube T5T6-145-25-DWM, T5, 1448 mm, 25 Watt, pure white
METOLIGHT LED-tube T5T6M, 1448 mm, 25 W, 3000 lm, pure white, frosted
T5-LED-Tube to be used in luminaires suitable for 35 / 49 / 80 Watt CFL-Tubes
direct connection to 110-255 V AC mains voltage - not to be used with dimmers
T5T6 tubes in length 1448 mm are mainly used in grid ceiling lights, wall lights, mirror cabinets, shelves etc. Common T5 fluorescent tubes often come with a very short shelf life. The LED tube T5T6M comes with a matted, unbreakable PC shell that distributes the light at about 140 °. This tube is also available with clear shell (series T5T6C). The G5-sockets can be rotated, so that the tube can be aligned correctly in luminaires with side view sockets. The SMDs of brand EPISTAR offer an efficiency of 130 lm / W, CRI Ra> 80 and are in accordance with the energy class A ++. The internal power supply and wiring are double-insulated and comply with VDE regulations according to DIN EN 62776 (VDE 0715, Part 16): 2012-02.
This T5T6 led tube can be operated directly on the mains voltage. Operation on dimmers is not possible. Existing ballast must be removed by a qualified electrician and the G5 sockets must be rewired so that the LED tube can be operated directly on the mains voltage. A conversion guide accompanies each shipment. After lighting remodeling a test according to DIN VDE 0701-0702 must be carried out.
Please note that from length 1148 mm, the LED tubes have to be additionally secured with cable ties and adhesive pads, since the weight allowable for G5 lampholders 250 g exceeds about 70 g.
Available light colours:
warm white (3000K9, nature white (4000K), poure white (5000K), cold white (6000K)
warm white + cold white: MOQ 25 pcs, lead time 4 weeks
Warranty:
This led tube , we provide a 3 year warranty ( see warranty terms in the shop download area )
Asmetec Quality:
Each tube is checked in Kirchheimbolanden for proper operation prior to shipment with us. You can request for free each batch a test report from our photometry. We create data for light calculation also in our own laboratory light - IES.
Note:
At each converted luminaire checks must be performed, which demonstrate that the luminaire is safe. It is recommended to DIN VDE 0701-0702 "Inspection after repair, modification of electrical appliances - Periodic inspection of electrical appliances - General requirements for electrical safety" apply. The converted light must be provided with a new label.
Technical Data
Beschreibung | Daten / Data | Description |
Markenname | METOLIGHT | Brand name |
Modell | LEDtube 145-T5T6-25 | Model |
EAN | 4251192840615 | EAN |
Betriebsspannung | 110 - 250 V AC | Input Voltage |
Gesamtleistung | ~ 25,2 Watt | Input Power |
Leistungsfaktor | Pf > 0,90 | Power factor |
Vorschaltgerät | ohne - none | Ballast |
Dimmbar? | nein / no | Dimmable? |
Lichtquelle | 192 x EPISTAR SMD2835 | Light Source |
Energieklasse | D | Energy Class |
auf einer Skala von A bis G (wenig effizient) / on scale of A to G (less efficient) | ||
Photobiolog. Klasse | 1 | Photobiolog. Class |
Lichtwinkel | 120°-140° | Beam Angle |
Lichteffizienz | ca. 130 lm/W | Light Efficacy |
Warmweiss | 2700 - 3000K - 2700 lm - Ra > 80 | Warm White |
Naturweiß | 3800 - 4200K - 2800 lm - Ra > 80 | Nature White |
Tagweiß | 4800 - 5300K - 3000 lm - Ra > 80 | Pure White |
Kaltweiß | 5800 - 6500K - 3200 lm - Ra > 80 | Cold White |
LED-Lebensdauer | < 30.000 h | LED-Life |
Schaltzyklen (ein/aus) | > 120.000 | Switch Cycles (on/off) |
Sockel | G5 | Base |
Lampenkörper | Alu / PMMA | Bulb Body |
Abmessung | 22 mm Durchmesser x 1448 mm lang (diameter x length) | Sizes |
Gewicht | ~ 320 g | Weight |
Normen | EN 50581:2012, EN55015:2013, EN60598-1:2009, EN60598-2-2:2012, EN60968:1990, EN60969, EN61000-3-2/2006, EN61000-3-3:2013, EN 61547:2013, EN62031:2008, EN62321:2013, EN62471:2008, EN62493:2010, EN62560:2012, EN 62776 | Standards |
Toleranz techn. Daten | +/- 10% | Tolerance techn. Data |
Hinweis | Nur bei stromfrei geschalteten Leuchten installieren, sonst Stromschlaggefahr durch eingeschaltetes Vorschaltgerät. / Installation only when luminaire is powered off to avoid electrical shock caused by ballast. | Note |
Hinweise | Notes |
Verwendungszweck | Application |
LED-Röhre als Retrofit für Leuchtstoffröhren für allg. Beleuchtungsanwendung im Innenbereich | LED-tube retrofit for common CFL-tubes, lighting application indoor |
Besonderheiten | Specials |
LED-Röhre zum Anschluss an Einzel-KVG, VVG und 230 Volt AC direkt, jedoch nicht an dimmbare EVG oder elektronische EVG | LED-tube for direct connection to magnetic ballast or direct 230 Volt AC, not suitable for dimmable or electronic ballast |
Installation | Installation |
In Leuchten mit KVG/VVG und Fasssung G5 anstelle bisheriger Leuchtstoffröhren, Röhrenwechsel nur bei stromfrei geschalteten Leuchten vornehmen! Vorhandenen Starter gegen abgesichertern LED-Starter austauschen. Röhren ab 100 cm Baulänge zusätzlich mit Kabelbinder sichern | In luminaires with magnetic ballast and G5 socket to replace common CFL. Change existing starter by LED starter. Change tubes only when power is off. Tubes longer than 100 cm must be secured by additional cable ties. |
Hinweise | Notes |
Wie bei allen LED-Leuchtmitteln ist auf ausreichende Luftzirkulation zu achten, damit die LED-Lampe nicht überhitzt. Die Gesamtenergieeffizienz und Lichtverteilung dieses LED-Leuchtmittels wird von der Bauart der Lichtanlage bestimmt, in der es verwendet wird. Messdaten unterliegen üblichen Toleranzen. Daten gem. Asmetec-Labor bzw. nach Werksangaben sowie. EU 874/2012, 2010//30/EU, 2011/65/EU | As with all LED-Lights take care for sufficient air ventilation to prevent LED overheating. The total efficiency and light distribution of this LED depends on the structure of the luminaire where it is used in. Technical data subject common tolerances. Measure data acc. Asmetec Test lab or original manufacturer data and acc. EU 874/2012, 2010//30/EU, 2011/65/EU |
Entsorgung | Waste Treatment |
LED-Leuchtmittel enthalten Wertstoffe. Bitte geben Sie die Lampen nach Gebrauch beim Wertstoffhof ab oder senden Sie sie an Asmetec zum Recycling zurück. | LED-lamps contain valuable raw materials. Please dispose them after use at the Local Court of Value Materials or return them for free disposal to Asmetec. |
Prüfberichte | Test Reports |
Individuelle Prüfberichte zu colorimetrischen, photometrischen und elektrischen, elektromagnetischen Daten erstellen wir auf Wunsch im eigenen Labor. | Individual test reports for colorimetric, photometric, electrical and electromagnetical data upon request made in own lab. |
Technische Daten | Technical Data |
Die junge LED-Technik unterliegt einer stetigen Veränderung. LEDs und Treiber werden immer effizienter. Die angegebenen technischen Daten können daher zur Produktverbesserung ohne vorherige Ankündigung geändert werden. | The young LED-Technology undergoes a steady development . LEDs and drivers are getting more efficient. The technical data given thus may be changed without prior notice to improve our products. |